How does a quadrupole mass spec work?
This type of mass analyzer separates ions based on the stability of their flight trajectories through an oscillating electric field in the quadrupole. The field is generated when a radio frequency (RF) voltage is applied between one pair of opposing rods within the quadrupole.
What is deflected most in a mass spectrometer?
Lighter ions are deflected more than heavier ones. the charge on the ion. Ions with 2 (or more) positive charges are deflected more than ones with only 1 positive charge.
What is mass quadrupole?
A quadrupole or quadrapole is one of a sequence of configurations of things like electric charge or current, or gravitational mass that can exist in ideal form, but it is usually just part of a multipole expansion of a more complex structure reflecting various orders of complexity.
What is a quadrupole mass analyzer used for?
Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications.
What is the function of the quadrupole?
As the name implies, it consists of four cylindrical rods, set parallel to each other. In a quadrupole mass spectrometer the quadrupole is the mass analyzer – the component of the instrument responsible for selecting sample ions based on their mass-to-charge ratio (m/z).
How does quadrupole time of flight mass spectrometry work?
Functionality of Q-TOF MS: The Q-TOF MS uses a quadrupole (four parallel rods arranged in a square formation), a collision cell, and a time of flight unit to produce spectra. Lighter ions accelerate faster down the flight tube to the detector, thus determining the ions’ mass-to-charge ratios.
How does deflection work in mass spectrometry?
Deflection is the magnetic bit. Here, the ions are deflected by a magnetic field, and the extent of deflection is again dependent on mass. So, ions of different masses travel through the spectrometer at different speeds.
How are ions deflected in a mass spectrometer?
The ions are accelerated so that they all have the same kinetic energy. The ions are then deflected by a magnetic field according to their masses. The lighter they are, the more they are deflected.
What is quadrupole effect?
A quadrupolar nucleus is one that has a quantum spin number greater than ½. Such nuclei have a lower symmetry than spin-½ nuclei. The quadrupole moment that varies between nuclei is a measure of this asymmetry. Their energies split upon the application of a magnetic field into multiple levels (fig. 1).
What is the function of quadrupole?
What is the notable advantage of the quadrupole mass spectrometer?
Quadrupole mass analyzers have several advantages such as no requirement for very high vacuum (> 10−7 Torr), and their relatively fast and simple operation for high-throughput analysis. Disadvantages include low transmittance, a low m/z cutoff, and low (generally unit) resolution.
What is a quadrupole mass spectrometer?
A quadrupole mass spectrometer consists of an ionizer (bombardment by electrons from a hot filament), an ion accelerator, and a mass filter consisting of four parallel metal rods arranged as in the figure above.
How is a magnetic field generated in a quadrupole?
The field is generated when a radio frequency (RF) voltage is applied between one pair of opposing rods within the quadrupole. A DC offset voltage is then applied to the other pair of opposing rods.
How many parallel rods are there in a quadrupole?
-ve +ve The quadrupole consists of four parallel rods. The opposing rods have the same polarity whilst adjacent rods have opposite polarity. Each rod is applied with a DC and an RF voltage.Ions are scanned by varying the DC/Rf quadrupole voltages.
How to optimize quadrupole mass analyzer resolution?
Quadrupole mass analyzer. The resolution ( R) of quadrupole mass analyzers is directly proportional to the number of RF cycles ( n) that an ion undergoes. It therefore follows that increasing the RF frequency is a means by which quadrupole resolution can be optimized.